Parameter Description Value
<option> Serial port direction The value options of this parameter and
the value meanings vary according to the
server model. You are advised to run the
ipmcget -d serialdir command to view
the value options.
For the server, the options are as follows:
0: switch from PANEL COM to SYS
COM
1: switch from PANEL COM to
iBMC COM
2: switch from SOL COM to SYS
COM
3: switch from SOL COM to iBMC
COM
To set the panel serial port as the iBMC
serial port, run the ipmcset -d serialdir -
v 1 command.
l To set the serial port by using a jumper, do as follows:
a. Power off the server and remove the power cables.
b. Place the jumper cap on COM_SW pins. For details about the jumper position, see
2.6 Mainboard and iBMC Card Connectors.
c. Connect the power cables and power on the server.
Step 2 Use a serial cable to connect the terminal serial port and the server serial port.
Step 3 Open HyperTerminal and set the following parameters:
l Bits per second: 115200
l Data bits: 8
l Parity: None
l Stop bits: 1
l Flow control: None
Figure 14-4 shows the port settings.
TaiShan 2280 V2 Server
User Guide
14 Common Operations
Issue 01 (2019-07-01) Copyright © Huawei Technologies Co., Ltd. 150