Torch Connect Console
3
104 809970 Field Service Bulletin XPR300
Install the control PCB
1. Tilt the PCB and align the CAN connector with the hole in the panel.
2. Push the CAN connector through the hole in the panel as you push the board down.
3. Use the screws to install the PCB. Tighten to 1.1 N∙m (10 in∙lb).
4. Install the pressure transducers. See Replace a pressure transducer on page 95.
5. Connect all of the wires. See Table 1 and Table 2 on page 105.
6. Install the top panel.
7. Install the manifold-side panel.
8. Supply the gas pressure to the cutting system.
9. Use the XPR web interface to make sure that the pressures are in the acceptable ranges.
For more information on the XPR web interface, see the Connect for
Communication in the XPR300 Instruction Manual (809480).