EasyManuals Logo
Home>Hypertherm>Welding System>XPR300

Hypertherm XPR300 Replacement Part Procedures

Hypertherm XPR300
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Plasma Power Supply
1
XPR300 Field Service Bulletin 809970 37
Replace the 48 V power source
Remove the 48 V power source
See Control side view 1 on page 126 for location and part number.
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. See Remove the right-side (liquid-cooling-side) panel on page 60.
c. See Remove the left-side (control-side) panel on page 61.
Keep all nuts and screws that you remove.
2. On the liquid-cooling side of the plasma
power supply, remove J7 and J8 from
the fan power distribution PCB.
3. On the control side, remove the
connector covers from the power
source.
4. Loosen the 4 screws to remove the
wires.

Table of Contents

Other manuals for Hypertherm XPR300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR300 and is the answer not in the manual?

Hypertherm XPR300 Specifications

General IconGeneral
BrandHypertherm
ModelXPR300
CategoryWelding System
LanguageEnglish

Related product manuals