Torch Connect Console
3
XPR300 Field Service Bulletin 809970 97
Replace a solenoid valve (V4-V10, V12)
See Torch connect console manifold side – view 2 on page 142 for
location and part number.
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. Remove the gas pressure from the cutting system.
c. Remove the top panel.
See Torch connect console top panel and side panels on page 114.
Keep all nuts and screws that you remove.
2. Use the edge of the connector to disconnect the wire from the control PCB.
Be careful not to pull the wires out of the solenoid valve connector.