EasyManua.ls Logo

Hypertherm XPR300 - How to Set the Regulators; Set the N Regulator

Hypertherm XPR300
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas Connect Consoles
2
XPR300 Field Service Bulletin 809970 85
How to set the regulators
This procedure is for when the regulators need to be adjusted in the field.
The N
2
and Ar OptiMix gas connect console (078633) regulators are set at Hypertherm before the
regulators are installed into the gas connect console. The regulators are set in a dynamic condition,
when gas is flowing, with 7.9 bar 8.6 bar (115 psi – 125 psi)
on the inlet and 6.9bar (100psi) on
the outlet. There is a 1.6 mm (0.063 inch) orifice downstream.
When to adjust regulators:
If your N
2
Shield inlet (P4) pressure is above 7.5bar (110psi) or below 6.2bar (90psi).
If your Ar Shield Inlet (P4) pressure is above 7.5 bar (110 psi) or below 6.2 bar (90 psi).
Set the N
2
regulator
1. Install one of the following sets of consumables:
300 A O
2
/Air
300 A N
2
/N
2
300 A Mix/N
2
170 A O
2
/Air
170 A N
2
/N
2
170 A Mix/N
2
2. Use the XPR web interface to load one of the following processes:
2100 for the 300 A consumables
2057 for the170 A consumables
3. Remove the cover from OptiMix gas connect console.
4. Pop the N
2
regulator knob up so the orange indicator is visible.
5. Go to Gas System in the XPR web interface.
N
2
Ar

Table of Contents

Other manuals for Hypertherm XPR300

Related product manuals