Hypertherm XPR300 Replacement Part Procedures

Hypertherm XPR300
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
Torch Connect Console
3
XPR300 Field Service Bulletin 809970 107
Install a proportional valve
1. Make sure that the 2 small O-rings are in the new base.
2. Align the arrow on the top of the base with the arrow on the manifold.
3. Use the 2 screws to install the base. Tighten to 1.6 N∙m (14 in∙lb).
Make sure that the stem O-ring is against the brass piece. If not, you can
damage the O-ring.
4. Install the base cover.
5. Install the coil/solenoid.
6. Install the nut. Tighten to 3.3 N∙m (29 in∙lb).
7. Install the connector.
8. Install the screw.
9. Install the control PCB. See Install the control PCB on page 104.
10. Install the manifold-side panel.
11 . Install the top panel.