Plasma Power Supply
1
XPR300 Field Service Bulletin 809970 25
Replace the solid state relay
See Fans on page 121 for location and part number.
1. Complete the following procedures:
a. Remove the power from the cutting system.
b. See Remove the right-side (liquid-cooling-side) panel on page 60.
Keep all nuts and screws that you remove.
2. Loosen the wire screws and remove the wires.
3. Remove the 2 mounting screws .
4. Remove the solid state relay.
5. Use the 2 mounting screws to install the solid state relay with T1, 2 in the upper-left corner, as
shown.
6. Install the wires as shown and tighten the wire screws.
7. Install the right side panel.
1
T1
2
L1
1
A1 (+)
3
A2 (-)
4
3
4
2
1
White
Black
Red
Black
1
22
Output or load side Input or control side
2

Table of Contents

Other manuals for Hypertherm XPR300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR300 and is the answer not in the manual?

Hypertherm XPR300 Specifications

General IconGeneral
Cutting Current300 A
Duty Cycle100% at 300 A
TechnologyX-Definition Plasma
Gas SupplyOxygen, Nitrogen, Air
Cutting Capacity (Mild Steel)38 mm (1.5 in)
Severance Capacity (Mild Steel)75 mm (3 in)
Pierce Capacity (Mild Steel)50 mm (2 in)
Input Voltage200–480 V, 3-PH, 50/60 Hz