EasyManua.ls Logo

Hypertherm XPR300 - Page 70

Hypertherm XPR300
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas Connect Consoles
2
70 809970 Field Service Bulletin XPR300
6. Connect J8.
7. Install the wire to the capacitor, J7, and J5. Angle the connector for J5 to the right.
8. Connect the following connectors:
J1 - The wire from the high-frequency, high-voltage transformer.
J2 - The wire from the high-frequency, high-voltage transformer and wire from the coil
assembly.
J3 - The wires to the primary input of the high-frequency, high-voltage transformer.
9. Install the high-voltage-side panel.
10. Install the insulator panel.
11 . Install the top panel.

Table of Contents

Other manuals for Hypertherm XPR300

Related product manuals