84  IBM System Storage DS3500: Introduction and Implementation Guide
RDAC implementation
RDAC is implemented between the HBA driver and the operating system disk driver, 
operating as a low-level filter driver. It has the following advantages:
ň° It is much more transparent to the OS and applications.
ň° I/O controls at the HBA driver level are not as tightly coupled to the OS as those at the disk 
driver level. Consequently, it is easier to implement I/O control functionality in the 
MPP-based RDAC driver for routing functions.
Because the driver is positioned at the HBA level (see Figure 3-26), it has access to the SCSI 
command and sense data interface of the HBA driver and therefore can make more informed 
decisions about what to do in the case of path failures.
Figure 3-26   Linux RDAC/MPP driver
DMM for Linux
At the current time DMMP for Linux is only supported with the SLES 11 release of Linux. 
There is currently no Redhat version of this driver supported today. With the SLES 11 the 
following requirements must be adhered to for the driver to function:
ň° OS version: SLES11.0 with the following patch installed
ň° patch installed: lsi-scsi_dh_rdac-kmp-default-01.00_2.6.27.19_5-1
ň° kernel upgraded to 2.6.31.5-0.16-default
ň° DMM version: device-mapper-1.02.27-8.6
For detailed instructions on how to implement and use DMM with SLES 11 see Chapter 20, 
âSuSE Linux configuration guideâ on page 603.
3.6.10  Function of Auto-Logical Drive Transfer feature
In a DS3500 Storage System equipped with two controllers, you can provide redundant I/O 
paths with the host systems. There are two separate components that provide this 
redundancy: a multipathing driver and Auto-Logical Drive Transfer (ADT).
ADT for logical drive-level failover
ADT is a built-in feature of controller firmware that allows logical drive-level failover rather than 
controller-level failover (as is the case with RDAC).
ň° ADT-disabled failover:
The multi-path software will send a SCSI Mode Select command to cause a change in 
volume ownership before using the alternate path. All logical drives on the preferred 
Note: In Linux, RDAC cannot be installed with the Installation Wizard. If you need RDAC, 
you have to download and install it separately. 
Note: ADT is not a failover driver. ADT provides storage systems with the flexibility to work 
with certain third-party failover software.