component in the drive channel fails, the DS3500 controllers can still access the EXP3500 
expansion enclosures in the redundant drive-channel pair.
4.6.2  Drive channel cabling rules
You should always follow these two basic connection rules when attaching EXP3500 
enclosures to a DS3500 storage subsystem:
ň° Connect the drive expansion SAS port on the DS3500 controller to the SAS IN port on the 
EXP3500. 
ň° Connect the SAS OUT port on the EXP3500 to the SAS IN port on the next EXP3500.
Attention: The EXP3500 ships with one ESM installed. If you are going to attach the 
EXP3500 to a dual controller DS3500 storage subsystem then you must install a second 
ESM in the EXP3500 expansion enclosure to provide redundant drive paths to the 
EXP3500 enclosures. Connecting an EXP3500 with one ESM installed to a DS3500 with 
two controllers installed is not a supported configuration.