4.6.3  Single controller DS3500 with one or more EXP3500 enclosures
Figure 4-16 shows the SAS connections between a single controller DS3500 subsystem and 
three EXP3500 enclosures, with a single ESM installed in each EXP3500. You should use the 
two connection rules above to connect the SAS ports on the DS3500 and the EXP3500s as 
shown. 
Figure 4-16   EXP3500 attachment - single controller and single ESM configuration 
4.6.4  Dual controller DS3500 with one EXP3500 enclosure
In this section we describe how to correctly cable a dual controller DS3500 to a single 
EXP3500 enclosure with two ESMs installed. This configuration provides redundancy on the 
drive-side connections. Figure 4-17 on page 103 shows the SAS cable connections in this 
configuration.
Note: The configuration shown in Figure 4-16 is a fully functional configuration but there is 
no redundancy on the drive side connections. If there is a fault with any one of the 
EXP3500 enclosures or the ESMs or a SAS cable, then there will be a loss of connection 
to the drives in all the EXP3500s that are connected below the point of failure. This 
situation can be avoided by using a configuration with two controllers in the DS3500 and 
two ESMs installed in each EXP3500 that is connected to the DS3500.