Chapter 20. SuSE Linux configuration guide  611
Draft Document for Review March 28, 2011 12:24 pm Linux Config.fm
 title SUSE Linux (2.6.27.19-5-default) with MPP support
root (hd0,1)
kernel /boot/vmlinuz root=/dev/disk/by-id/scsi-35000c500009c6dcb-part2 
splash=silent resume=/dev/disk/by-id/scsi-35000c500009c6dcb-part1 elevator=cfq 
showopts vga=0x317
initrd /boot/mpp-2.6.27.19-5-default.img
It is recommended to take the information for the root and resume parameters from the 
previous line by default.
4. Reboot the server and when the grub menu appears select the SUSE Linux 
(2.6.27.19-5-default) with MPP support option as shown in Figure 20-11. It is possible 
to make this selection as default by changing the default parameter in the menu.lst file.
Figure 20-11   Boot menu when server starts after RDAC installation
20.1.3  Setting up the DS3500 logical drives and host mapping
Map the logical drive(s) to the SuSE operating system by using the normal procedure as 
described in Chapter 11, âAdministration - Mappings Tabâ on page 281.
One of the important things to consider, is using the correct Host type when mapping the 
logical drive to the host from the IBM Storage Manager as shown in Figure 20-12.
Figure 20-12   Defining the Host Type of the host
When you define the host port, the host type of the attached host is defined as well. Through 
this information, the DS Storage System modifies the NVSRAM settings to behave according 
to the host type defined. 
The most common of the specifications that differ according to the host type setting is the 
Auto Volume Transfer function (AVT), which is set as enable for certain host types, and 
disable for others. It is important to carefully choose the correct host type from the list of