This button starts an automatic discovery of new storage subsystems (Figure 6-22) by 
sending in-band and out-of-band broadcasts. If it finds directly attached storage systems or 
hosts running the DS3500 Storage Manager agent (with an attached Storage subsystem), it 
adds these storage subsystems to the Enterprise Management window. 
Figure 6-22   Automatic Discovery
Rescan selected host for new storage subsystems
Figure 6-23   Rescan Host button
If you are using a host running an agent to manage your storage subsystems, you can use 
this button to only rescan the selected host. To do this task, highlight the host, click this 
button, and the Rescan window appears. Select OK and the host will scan for newly attached 
storage devices. 
Add Storage Subsystem to view
Figure 6-24   Add Storage Subsystem to view
Click this button to display the Add Storage Subsystem window. Here you can add systems 
manually to your Enterprise window view. For out-of-band management, you have to provide 
the IP address or host names of the controllers (Figure 6-25 on page 179). If the storage 
subsystem has dual controllers, you must provide the IP address of both controllers.
Note: If your subsystem is not discovered automatically by the wizard (for example, 
because it is in another broadcast domain), you can add it manually, as described in âAdd 
Storage Subsystem to viewâ on page 178.