51
▋Camber▋sytem【CAMBER▋SYSTEM】
▋▋Function▋Explanation
It is possible to set an airplane (Glider in particular) which has full span ailerons or aps +
ailerons on the main wing giving full-span moveable control surfaces. These control surfaces can be moved
up and down simultaneously to change the wing type. Because changing the wing type can vary the rate of
descent and the drag, it is possible to change the ight endurance and the glide ratio. These settings can be
set for each Flight Mode. In addition, because the delay time during transition can be adjusted, the aircraft will
not react wildly. During this delay time, rapid cancellation is possible using the elevator stick. (Break Function)
▋▋Setting▋Method
There are two ways of setting the amount of Camber offset in each flight mode. One is to set it using this
function, and the other method is changing the Trim position.
It is possible to set the numerical value of Camber o-set with a desired “DELAY” and “BREAK” in the menu.
O Set Value (OFFSET)
Set the Oset value on both FLAP and Flaperon for each ight mode.
፧
FLAPERON
Set each Flaperon value for the Left Aileron and Right Aileron.
፧
FLAP
Set single Flap using “FLAP”, For “Dual Flaps” set the “LFLP” (Left Flap) and “RFLP” ( Right Flap) values
independently.
፧
Four Aileron (4-AILE)
"LAL1"(Left Aileron 1), "RAL1"(Right Aileron1), "LAL2"(Left Aileron2), "RAL2"(Right Aileron2), Set the O
set on these Aileron independently.
Time Delay (DELAY)
It is possible to set the time delay when switching between dierent ight mode on “O Set Amount ” or the
“Trim Amount”. “INH” is no Time Delay. The time delay duration can be set between 0.1 to 6.0seconds. “HOLD”
means without Time Delay.
፧
Flap Trim 「FLAP TRIM」
፧
Flaperon Trim 「FPRN TRIM」
፧
Elevator Trim 「ELEV TRIM」
Break Function (BREAK / BREAK BY ELEV STICK)
This sets the range of the Break function using the Elevator Stick. This can be “INH” or “ACT”. Because the
delay operation will be discontinued even if the stick exceeds the numerical value only momentarily, it allows
you to respond to sudden changing circumstances. Set the position (numerical value) for the elevator where it
should “ACT” using the “BREAK BY ELEV STICK” function.
To prevent mistaken operation of the Camber Position (Trim Position) that has been set in each of the Flight
Modes, the sensitivity of the trim can be set to zero. After setting the number of steps of the FLAP and FPRM
Trim in the Trim System screen in the System List, these should be set to zero. By doing so, even though the
Trim lever will not actually operate, the set positions will remain memorized.
▋▋Caution▋Note
Actually operate the servos and carefully conrm the settings before ying.