JMA-9100 Instruction Manual > 9.TROUBLE SHOOTING AND AFTER-SALES SERVICE > 9.1 FAULT FINDING
9ļ¼5
9
Table9-7ļ¼ List of Conditions Messages
Message Class Description
ALR No.
i
i. ALR No.: Unique alarm number in ALR sentence and ACK sentence
Battery Dead
Warning
The battery is dead.
Battery Low
Warning battery is weakening.
GPS (HDOP)
Warning
The HDOP level is increased (Decrease in the GPS
accuracy.).
MON Test Warning Performance monitor is active.
Scanner Rotating
Warning The scanner is rotating (When transmitter is standby
state.).
Table9-8ļ¼ List of Interswitch Alarms and Messages
Message Class Description
ALR No.
i
i. ALR No.: Unique alarm number in ALR sentence and ACK sentence
Connection
Masked
INFO Inhibition of control / connection is set.
ISW (Data)
Alarm
No communication, data mismatched, or checksum error. 327
ISW Busy INFO
Access to the ISW menu was made during interswitching.
ISW Complete INFO The switchover of the Interswitch ended normally.
ISW Error
INFO The interswitch is disabled.
ISW Standby
INFO The Interswitch recovered normally.
ISW Straight
INFO The interswitch is forced to change the connection
into straight.
ISW Time Out
INFO Failed in switching.
Master Range CHG
INFO The range of the own display unit has changed due
to change in the range of the master display unit.
Master Standby
INFO The master display unit does not transmit any
signals.
Pattern CHG Failed
INFO Connection change failed.
TXRX Standby
INFO The scanner unit is in the standby mode.
Update ISW
Software
INFO Tried to enter new TXRX function, when interswitch
software used old version.