Fig B-12: Primary Power System Diagram
POWER CONTROL
CIRCUIT
INTERSWITCH=1A
OPERATION UNIT=0.5A(typ)
GYRO I/F CIRCUIT=0.1A(typ)
SCANNER
X BAND_2.5A, S BAND_3.0A
RADAR PROCESS CIRCUIT = 1.2A(typ)
ARPA PROCESS CIRCUIT = 0.15A(typ)
AIS PROCESS CIRCUIT = 0.15(typ)
TERMINAL BOARD = 1.0A(typ)
AC100-115V
AC220-240V
50/60Hz,1φ
SCANNER
MOTOR
POWER
AC100/230V
1φ/1φ,
OVER VOLT AGE
PROT ECTION
100V: 148+ /-2V
220V: 295+ /-2V
AC100-115V
AC220-240V
50/60Hz,1φ
RADAR PROCESS CIRCUIT = 2.2A(typ)
ARPA PROCESS CIRCUIT = 0.1A(typ)
AIS PROCESS CIRCUIT = 0.1(typ)
TERMINAL BOARD = 0.2A(typ)
RADAR PROCESS CIRCUIT = 0.1A(typ)
TERMINAL BOARD = 0.4A(typ)
RADAR PROCESS CIRCUIT = 0.1A(typ)
TERMINAL BOARD = 0.1A(typ)
BATTRY
DC24V
OPERATION UNIT = 0.1A
P+12V
+48V±3V
+5. 0V
+3. 3V
-12V
+12V
CIRCUIT
BREAKER
20A
LINE FI LTER
VOLTAGE SELCT
SWITCH
MONITOR UNIT
POWER
SCANNER MOTOR
POWER
FAN ALM POWER CONTROL