NOTE: All nonconductive surfaces on the router must be removed from all
threads and connection points to ensure electrical continuity.
Grounding Cable Lug Specifications
The grounding cable lug is used to secure the grounding cable to the grounding points
on the chassis. The grounding cable lug attaches to the grounding cable and is secured
to the router by two SAE 10-32 screws. We recommend using washers between the
grounding lug and the screws. The grounding cable lug, screws, and washers are supplied
with the router. See Figure 21 on page 77 for AC systems and Figure 22 on page 78 for 24
VDC systems.
Figure 21: Grounding Cable Lug for MX104 AC Systems
77Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Preparation Overview