lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del
tamaño apropiadopara loscables que se utilicen,y tendránque sujetartanto
el aislante como el conductor.
Varning! När flertrådiga ledningar krävs måste godkända ledningskontakter
användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken dessa kontakter måste varaavpassad till ledningarnaoch måste
kunna hålla både isoleringen och ledaren fastklämda.
Related
Documentation
General Safety Warnings for Juniper Networks Devices on page 218
General Electrical Safety Warnings for Juniper Networks Devices on page 241
Site Electrical Wiring Guidelines for MX104 Routers
Distance Limitations for Signaling on page 251
Radio Frequency Interference on page 251
Electromagnetic Compatibility on page 251
Distance Limitations for Signaling
Improperly installed wires can emit radio interference. In addition, the potential for damage
from lightning strikes increases if wires exceed recommended distances or if wires pass
between buildings. The electromagnetic pulse (EMP) caused by lightning can damage
unshielded conductors and destroy electronic devices. If your site has previously
experienced such problems, you might want to consult experts in electrical surge
suppression and shielding.
Radio Frequency Interference
You can reduce or eliminate the emission of radio frequency interference (RFI) from your
site wiring by using twisted-pair cable with a good distribution of grounding conductors.
If you must exceed the recommended distances, use a high-quality twisted-pair cable
with one ground conductor for each data signal when applicable.
Electromagnetic Compatibility
If your site is susceptible to problems with electromagnetic compatibility (EMC),
particularly from lightning or radio transmitters, you might want to seek expert advice.
Strong sources of electromagnetic interference (EMI) can destroy the signal drivers and
receivers in the router and conduct power surges over the lines into the equipment,
resulting in an electrical hazard. It is particularly important to provide a properly grounded
and shielded environment and to use electrical surge-suppression devices.
WARNING: The intrabuilding port(s) of the equipment or subassembly is
suitable for connection to intrabuilding or unexposed wiring or cabling only.
The intrabuilding port(s) of the equipment or subassembly MUST NOT be
251Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Electrical Safety Guidelines and Warnings

Table of Contents

Other manuals for Juniper MX104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX104 and is the answer not in the manual?

Juniper MX104 Specifications

General IconGeneral
Product NameMX104
Product SeriesMX Series
Switching Capacity80 Gbps
Throughput80 Gbps
Operating SystemJunos OS
Humidity5% to 90% non-condensing
Interfaces10 Gigabit Ethernet, Gigabit Ethernet
Power SupplyDual redundant AC or DC
CoolingFront-to-back airflow
Memory8 GB
Operating Temperature0°C to 40°C