DC Power Electrical Safety Warnings for Juniper Networks Devices on page 248
MX104 DC Power Cable and Lug Specifications on page 100
MX104 DC Power Cable and Lug Specifications
DC Power Cable Lug Specifications on page 100
DC Power Cable Specifications on page 100
DC Power Cable Lug Specifications
Use cable lugs with the specifications shown in Figure 24 on page 100 to attach each DC
power cable to the DC power supply.
Figure 24: DC Power Cable Lug
CAUTION: Before router installation begins, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with
an incorrectly attached lug can damage the router.
DC Power Cable Specifications
You must supply two DC power cables for each DC power supply that meet the following
specifications: 14-AWG (2.08 mm
2
), minimum 90° C wire, or as required by the local
code.
Related
Documentation
Connecting DC Power Cables to the MX104 Router on page 117
Replacing an MX104 DC Power Supply on page 177
MX104 DC Power Electrical Safety Guidelines on page 247
Copyright © 2017, Juniper Networks, Inc.100