CHAPTER 10
Power Specifications
•
MX104 Power Consumption on page 93
MX104 Power Consumption
The MX104 router supports installation of up to two AC or DC power supplies in slots
labeled on the front of the router.
Table 67 on page 93 lists the power consumed by the MX104 router.
NOTE: The power consumption values are measured from the power source
and are based on systems that containredundant power supplies, redundant
Routing Engines, a fan tray, and are fully loaded with MICs.
Table 67: Power Consumed by MX104 Routers
ValueDescription
600 WPower consumed by the AC router (typical)
625 WPower consumed by the DC router (typical)
325 WPower consumed by the AC router without MICs (typical)
350 WPower consumed by the DC router without MICs (typical)
Related
Documentation
• Connecting DC Power Cables to the MX104 Router on page 117
• MX104 DC Power Electrical Safety Guidelines on page 247
• MX104 DC Power Specifications on page 99
93Copyright © 2017, Juniper Networks, Inc.