Issue the show chassis routing-engine command to check the status of the Routing
Engines. The output is similar to the following:
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 34 degrees C / 93 degrees F
CPU temperature 43 degrees C / 109 degrees F
DRAM 3840 MB (3840 MB installed)
Memory utilization 34 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 3 percent
Interrupt 3 percent
Idle 94 percent
Model RE-S-MX104
Serial ID CAAR5925
Start time 2013-05-24 16:33:54 IST
Uptime 2 days, 20 hours, 11 minutes, 15 seconds
Last reboot reason 0x200:normal shutdown
Load averages: 1 minute 5 minute 15 minute
0.13 0.04 0.01
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 36 degrees C / 96 degrees F
CPU temperature 42 degrees C / 107 degrees F
DRAM 3840 MB (3840 MB installed)
Memory utilization 23 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 2 percent
Idle 97 percent
Model RE-S-MX104
Serial ID CAAM6369
Start time 2013-05-24 16:34:14 IST
Uptime 2 days, 20 hours, 10 minutes, 47 seconds
Last reboot reason 0x200:normal shutdown
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00
Meaning The command output displays the Routing Engine slot number, current state (Master,
Backup, or Disabled), election priority (Master or Backup), and airflow temperature. The
command output also displays the total DRAM available to the Routing Engine processor,
the CPU utilization percentage, and the Routing Engine serial number for the slot.
Additionally, the command output displays when the Routing Engine started running,
how long the Routing Engine has been running, and the time, uptime, and load averages
for the last 1, 5, and 15 minutes.
Check the Uptime to ensure that the Routing Engine has not rebooted since it started
running.