General Site Installation Guidelines for the SRX1500 Services Gateway
The following precautions help you plan an acceptable operating environment for your
SRX1500 Services Gateway and avoid environmentally caused equipment failures:
•
For the cooling system to function properly, the airflow around the chassis must be
unrestricted. Allow sufficient clearance between the front and back of the chassis and
adjacent equipment. Ensure that there is adequate circulation in the installation location.
•
Follow the ESD procedures to avoid damaging equipment. Static discharge can cause
components to fail completely or intermittently over time. For more information, see
“Preventing Electrostatic Discharge Damage to the SRX1500 Services Gateway” on
page 118.
•
Ensure that the blank panels are installed into empty slots to prevent any interruption
or reduction in the flow of air across internal components.
NOTE: Install the services gateway only in restricted areas, such as dedicated
equipment roomsand equipment closets,in accordance with Articles110–16,
110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
• SRX1500 Services Gateway Physical Specifications on page 17
• SRX1500 Services Gateway Environmental Specifications on page 17
• Site Preparation Checklist for the SRX1500 Services Gateway on page 18
Copyright © 2017, Juniper Networks, Inc.20
SRX1500 Services Gateway Hardware Guide