4. Start your asynchronous terminal emulation application (such as Microsoft Windows
HyperTerminal) and select the appropriate COM port to use (for example, COM1).
5. Configure the serial port settings with the following values:
•
Baud rate—9600
•
Parity—N
•
Data bits—8
•
Stop bits—1
•
Flow control—none
6. Power on the services gateway. You can start performing initial software configuration
on the services gateway after the device is up.
Related
Documentation
Configuring the SRX1500 Services Gateway Using the CLI on page 78•
• SRX1500 Services Gateway Software Configuration Overview on page 71
Connecting to the SRX1500 Services Gateway from the CLI Remotely
To connect the services gateway to a network for out-of-band management:
1. Plug one end of an Ethernet cable with RJ-45 connectors into the MGMT port on the
front panel of the services gateway.
2. Plug the other end of the cable into the management device.
Related
Documentation
Accessing the CLI on the SRX1500 Services Gateway on page 77•
Configuring the SRX1500 Services Gateway Using the CLI
This sample procedure explains how you can create an initial configuration using CLI
commands to connect the SRX1500 Services Gateway to the network.
1. Verify that the device is powered on.
2. Log in as the root user. Do not enter a password.
3. Start the CLI.
root@%cli
root>
4. Enter configuration mode.
Copyright © 2017, Juniper Networks, Inc.78
SRX1500 Services Gateway Hardware Guide