CHAPTER 12
Installing the Rack Mounting Hardware
•
Preparing the SRX1500 Services Gateway for Rack-Mount Installation on page 49
•
Connecting the SRX1500 Services Gateway to the Building Structure on page 50
Preparing the SRX1500 Services Gateway for Rack-Mount Installation
You can mount an SRX1500 Services Gateway on four-post (telco) racks, enclosed
cabinets, and open-frame racks. Center-mount racks are not supported.
Before mounting the SRX1500 Services Gateway in a rack:
•
Verify that the site meets the requirements described in “Site Preparation Checklist
for the SRX1500 Services Gateway” on page 18.
•
Verify that you have the following parts available in your rack-mounting kit for the
SRX1500 Services Gateway:
•
Rack-mounting brackets
•
Screws
•
Verify that the racks or cabinets meet the specific requirements described in “SRX1500
Services Gateway Rack Requirements” on page 25.
•
Place the rack or cabinet in its permanent location, allowing adequate clearance for
airflow and maintenance, and secure it to the building structure. For more information,
see “SRX1500 Services Gateway Cabinet Airflow Requirements” on page 30.
•
Remove the gateway chassis from the shipping carton. For unpacking instructions, see
“Unpacking the SRX1500 Services Gateway” on page 45.