Table 12 on page 33 provides power cord specifications, and Figure 7 on page 33 depicts
the plug on the AC power cord provided for each country or region.
Table 12: AC Power Cord Specifications
Plug StandardsElectrical SpecificationCountry
AS/NZ 3112-1993250 VAC, 10 A, 50 HzAustralia
GB2099.1 1996 and
GB 1002 1996
(CH1-10P)
250 VAC, 10 A, 50 HzChina
CEE (7) VII250 VAC, 10 A, 50 HzEurope (except Italy and United Kingdom)
CEI 23-16/VII250 VAC, 10 A, 50 HzItaly
JIS 8303125 VAC, 12 A, 50 or 60 HzJapan
NEMA 5-15125 VAC, 10 A, 60 HzNorth America
BS 1363A250 VAC, 10 A, 50 HzUnited Kingdom
Figure 7: AC Plug Types
NOTE: Power cords and cables must not block access to services gateway
components or drape where people might trip on them.
Related
Documentation
SRX1500 Services Gateway AC Power Supply Electrical Specifications on page 33
SRX1500 Services Gateway DC Power Supply Electrical Specifications on page 34
SRX1500 Services Gateway DC Power Cable Specifications on page 34
SRX1500 Services Gateway Electrical Wiring Guidelines on page 31
SRX1500 Services Gateway AC Power Supply Electrical Specifications
Table 13 on page 34 lists the AC power supply electrical specifications for the SRX1500
Services Gateway.
33Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Power Requirements and Specifications