MULTICAL®603
KamstrupA/S∙Technicaldescription∙5512‐2029
A1_GB
06.2017
79
12.Averagingperio dofmin/maxPandQ
Theaveragingperiodusedinthecalculationofminimumandmaximumvaluesofpower(P)andflow(Q)canbe
adjusted.Theaveragingperiodisindicatedintheintervalof1…1440minutes.Readmoreabouttheaveragingperiod
ofmin./maxofPand
Qinparagraph7.5.
13.Heat/coolingshift(
hc
)
Thelimitforheat/coolingshift(
hc
)canbeadjustedintheSETUPloop,howeveronlyinmetersorderedasmetertype
6(heat/coolingmeter).Thevaluecanbeselectedintheinterval2…180.00Caswellasat250.00Ciftheuserwants
todisablethefunct ion.Thefunctionisenabledagainbysetting
thelimitatavalueinthevalidareaof2…180C.
Heat/coolingshiftispermanentlydisabledonothermetertypes,andthedisplaythusshows“Off”onallothermeter
typesthan6.Readmoreaboutheat/coolingshiftinparagraph7.4.
Metertype:1,2,3,4,5,
7 Metertype:6
Theframesaround“Off”illuminatesas
long as the primary key remains
activated.
Thefirstdigitflashesandeachdigitcan
nowbesetatavaluewithintherange
0…9.
Ifyouchooseavalueoutsidethevalid
interval(2…180.00C),thevalueis
automaticallyadjustedto250.00C,
whichindicatesthatthefunctionhas
beenswitchedoff.