12.๎Averaging๎perio d๎of๎min/max๎P๎and๎Q๎
The๎averaging๎period๎used๎in๎the๎calculation๎of๎minimum๎and๎maximum๎values๎of๎power๎(P)๎and๎flow๎(Q)๎can๎be๎
adjusted.๎The๎averaging๎period๎is๎indicated๎in๎the๎interval๎of๎1โฆ1440๎minutes.๎Read๎more๎about๎the๎averaging๎period๎
of๎min./max๎of๎P๎and
๎Q๎in๎paragraph๎7.5.๎๎
๎๎
๎
13.๎Heat/cooling๎shift๎(๏ฑ
hc
)๎
The๎limit๎for๎heat/cooling๎shift๎(๏ฑ
hc
)๎can๎be๎adjusted๎in๎the๎SETUP๎loop,๎however๎only๎in๎meters๎ordered๎as๎meter๎type๎
6๎(heat/cooling๎meter).๎The๎value๎can๎be๎selected๎in๎the๎interval๎2โฆ180.00๎๏ฐC๎as๎well๎as๎at๎250.00๎๏ฐC๎if๎the๎user๎wants๎
to๎disable๎the๎funct ion.๎The๎function๎is๎enabled๎again๎by๎setting
๎the๎limit๎at๎a๎value๎in๎the๎valid๎area๎of๎2โฆ180๎๏ฐC.๎
Heat/cooling๎shift๎is๎permanently๎disabled๎on๎other๎meter๎types,๎and๎the๎display๎thus๎shows๎โOffโ๎on๎all๎other๎meter๎
types๎than๎6.๎Read๎more๎about๎heat/cooling๎shift๎in๎paragraph๎7.4.๎๎
๎
Meter๎type:๎1,๎2,๎3,๎4,๎5,๎
7๎ Meter๎type:๎6๎
๎๎
The๎frames๎around๎โOffโ๎illuminates๎as๎
long๎ as๎ the๎ primary๎ key๎ remains๎
activated.๎๎
The๎first๎digit๎flashes๎and๎each๎digit๎can๎
now๎be๎set๎at๎a๎value๎within๎the๎range๎
0โฆ9.๎๎
If๎you๎choose๎a๎value๎outside๎the๎valid๎
interval๎(2โฆ180.00๎๏ฐC),๎the๎value๎is๎
automatically๎adjusted๎to๎250.00๎๏ฐC,
๎
which๎indicates๎that๎the๎function๎has๎
been๎switched๎off.๎๎
๎
๎ ๎