Series 2280 Precision DC Power Supply Reference Manual Section 7: SCPI command reference
077085503 / March 2019 7-79
[:SOURce[n]]:VOLTage:SLEW:RISing
This command specifies and queries the rising rate for the voltage source.
Recall settings
Instrument reset
Power cycle
Usage
[:SOURce[n]]:VOLTage:SLEW:RISing <value>
[:SOURce[n]]:VOLTage:SLEW:RISing?
[:SOURce[n]]:VOLTage:SLEW:RISing? DEFault
[:SOURce[n]]:VOLTage:SLEW:RISing? MINimum
[:SOURce[n]]:VOLTage:SLEW:RISing? MAXimum
Channel number: For single-channel instruments, the value is 1
The voltage rising rate: 10 V per second to 1000 V per second.
Details
Slew rate is defined as the maximum rate of change of output voltage per unit of time. The slew rising
rate is applied to any voltage increase.
When you turn on the output, the voltage rises at the specified rate.
Example
Set the voltage rising rate to 20 V per second.
Also see
[:SOURce[n]]:VOLTage:SLEW:FALLing (on page 7-80)