EasyManuals Logo
Home>Keithley>Measuring Instruments>2600B

Keithley 2600B User Manual

Keithley 2600B
897 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #887 background imageLoading...
Page #887 background image
Series 2600B
System SourceMeter® Instrument Reference Manual Appendix G:
Model 2400 emulation
2600BS-901-01 Rev. C / August 2016 G-13
Subsystem
Command
Supported
:SYSTem
:SYSTem:RCMode SINGle|MULTiple
No
:SYSTem
:SYSTem:RCMode?
No
:SYSTem
:SYSTem:RSENse <Bool>
Yes
:SYSTem
:SYSTem:RSENse?
Yes
:SYSTem
:SYSTem:RWLock <Bool>
Yes
:SYSTem
:SYSTem:RWLock?
Yes
:SYSTem
:SYSTem:TIME?
Yes
:SYSTem
:SYSTem:TIME:RESet
Yes
:SYSTem
:SYSTem:TIME:RESet:AUTO <Bool>
Yes
:SYSTem
:SYSTem:TIME:RESet:AUTO?
Yes
:SYSTem
:SYSTem:VERSion?
Yes
:TRACe
:TRACe:CLEar
Yes
:TRACe
:TRACe:DATA?
Yes
:TRACe
:TRACe:FEED SENSe[1]|CALCulate[1]|CALCulate2
Yes
:TRACe
:TRACe:FEED?
Yes
:TRACe
:TRACe:FEED:CONTrol NEXT|NEVer
Yes
:TRACe
:TRACe:FEED:CONTrol?
Yes
:TRACe
:TRACe:FREE?
Yes
:TRACe
:TRACe:POINts <NRf>|DEFault|MINimum|MAXimum
Yes
:TRACe
:TRACe:POINts? [DEFault|MINimum|MAXimum]
Yes
:TRACe
:TRACe:POINts:ACTual?
Yes
:TRACe
:TRACe:TSTamp:FORMat ABSolute|DELTa
Yes
:TRACe
:TRACe:TSTamp:FORMat?
Yes
:TRIGger
:ABORt
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:COUNt <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:COUNt?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:SOURce
IMMediate|TLINk|TIMer|MANual|BUS|NSTest|PSTest|BSTest
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:SOURce?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:ILINe 1|2|3|4
Partially
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:ILINe?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OLINe 1|2|3|4
Partially
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OLINe?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OUTPut
TENTer|TEXit|NONE
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure][:ASYNchronous]:OUTPut?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure]:DIRection SOURce|ACCeptor
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]][:TCONfigure]:DIRection?
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer <NRf>
Yes
:TRIGger
:ARM[:SEQuence[1]][:LAYer[1]]:TIMer?
Yes
:TRIGger
:INITiate[:IMMediate]
Yes
:TRIGger
:READ?
Yes
:TRIGger
:TRIGger:CLEAr
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:COUNt <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:COUNt? [DEFault|MINimum|MAXimum]
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:DELay <NRf>|DEFault|MINimum|MAXimum
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:DELay? [DEFault|MINimum|MAXimum]
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:SOURce IMMediate|TLINk
Yes
:TRIGger
:TRIGger[:SEQuence[1]]:SOURce?
Yes
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:ILINe 1|2|3|4
Partially
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:ILINe?
Yes
:TRIGger
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:INPut
Partially