SCPI Command *RST Settings
LIST:TOUTput:BOSTep 1 step set to OFF
LIST:TOUTput:EOSTep 1 step setto OFF
LIST:VOLTage 1 step set to 0.1% of rating
LXI:IDENtify OFF
OUTPut OFF
OUTPut:DELay:FALL 0
OUTPut:DELay:RISE 0
OUTPut:PROTection:MODE LOWZ
OUTPut:PROTection:USER OFF
OUTPut:PROTection:USER:SOURce NONE
OUTPut:PROTection:WDOG OFF
OUTPut:PROTection:WDOG:DELay 60
OUTPut:RELay:POLarity NORMal
RESistance 0
RESistance:STATe 0
SENSe:CURRent:RANGe:AUTO ON
SENSe:ELOG:CURRent:RANGe:AUTO ON
SENSe:ELOG:FUNCtion:CURRent OFF
SENSe:ELOG:FUNCtion:CURRent:MINMax OFF
SENSe:ELOG:FUNCtion:VOLTage OFF
SENSe:ELOG:FUNCtion:VOLTage:MINMax OFF
SENSe:ELOG:PERiod 0.1
SENSe:FAULt:STATe ON
SENSe:FUNCtion:CURRent 1
SENSe:FUNCtion:VOLTage 1
SENSe:SWEep:NPLCycles 1
SENSe:SWEep:OFFSet:POINts 0
SENSe:SWEep:POINts 3255 (60 Hz); 3906 (50 Hz)
SENSe:SWEep:TINTerval 5.12E–6
SENSe:THReshold<n>:AHOur 0
SENSe:THReshold<n>:CURRent 0
SENSe:THReshold<n>:FUNCtion VOLTage
SENSe:THReshold<n>:OPERation GT
SENSe:THReshold<n>:POWer 0
6 SCPI Programming Reference
293 Keysight N6900/N7900 Series Operating and Service Guide