2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-54
U157 Dev Time
Description
Displays the developer drive time for checking a figure, which is used as a reference when correct-
ing the toner control.
Purpose
To check the developer drive time after replacing the developer unit.
Method
1. Press the start key. The developer drive time is displayed.
Display Description
K Developer drive time. (K)
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U158 Dev Cnt
Description
Displays the developing count for checking.
Purpose
To check the developing count after replacing the developing unit.
Method
1. Press the start key. The current developer counts is displayed.
Display Description
K Developing count. (K)
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.