2NC/2NF/2NG/2NN/3P7/3P8/3P9
1-3-115
U910 Clr Coverage Dat
Description
Clears the accumulated data for the print coverage per A4 size paper and its period of time (as
shown on the service status report).
Purpose
To clear data as required at times such as during maintenance service.
Method
1. Press the start key.
2. Select [Execute].
Display Description
Execute The print coverage data is cleared.
3. Press the start key. The print coverage data is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U927 Clr Chg/Life Cnt
Description
Resets all of the counts back to zero.
Purpose
The total account counter and the machine life counter can be cleared only once if all count values
are 1000 or less.
Method
1. Press the start key.
2. Select [Execute].
Display Description
Execute All copy counts and machine life counts are cleared.
3. Press the start key. All copy counts and machine life counts are cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.