2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-57
U199 Fuser Temp
Description
Displays the detected fuser temperature.
Purpose
To check the fuser temperature.
Method
1. Press the start key. The fuser temperature is displayed.
Display Description
Fix Center Temperature in the center of the fixing. (°C)
Fix Edge Temperature in the edge of the fixing. (°C)
* : Temperature a acquired and re-displayed periodically.
Completion
Press the stop key. The screen for selecting a maintenance mode No. is displayed.
U203 Chk DP Ope
Description
Simulates the original conveying operation separately in the DP.
Purpose
To check the DP operation.
Method
1. Press the start key.
2. Place an original in the DP.
3. Select the mode to be operated.
Display Description
Mono Mono reading
Color Color reading
4. Select the item to be operated.
Display Description
ADP With paper, single-sided original.
RADP With paper, double-sided original.
5. Press the start key. The operation starts.
6. To stop continuous operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.