2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-59
U211 Set EH Connection
Description
Connection of enhancement apparatus is set up.
Purpose
It uses for a connection setup of enhancement apparatus without connection detection.
1. Press the start key.
2. Select [Duplex Unit].
Display Description
Duplex Unit A connection setup of a duplex unit.
3. Select On or Off.
Display Description
On Duplex unit is connect.
Off Duplex unit is not connect.
4. Press the start key. The setting is set.
5. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
* : When you change the setting of the U211, U343 display changed.
if U211 is set "Off" , U343 is not shown on Select Screen.
* : When U211 is set "Off", U343 is set "Off".
U223 Lock panel Ope
Description
Set the ON / OFF operation of the unit lock function.
Purpose
TTo limit the operation of the system menu on the operation unit.
The same settings as the operation panel lock function in the Command Center.
Method
1. Press the start key.
2. Select the item to be set.
Display Description
Unlock OFF the Lock of SystemMenu.
Partial Lock ON the Partial Lock function of SystemMenu.
Lock ON the Lock function of SystemMenu.
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
(Advanced model only)