2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-25
5. Change the setting value using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
For output example 1, increase the value. For output example 2, decrease the value
Figure 1-3-3
6. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U034 -------- U066 -------- U071
(P.1-3-33) (P.1-3-37)
Adjustment: LSU Out Left
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
[LSU Out Left]
Display Description
Setting
range
Initial
setting
Change in
value per step
MPT Paper feed from MP tray. -10.0 to 10.0 0 0.1
Cas1 Paper feed from cassette1. -10.0 to 10.0 -1.6 0.1
Cas2 Paper feed from optional cassette2. -10.0 to 10.0 -1.6 0.1
Cas3 Paper feed from optional cassette3. -10.0 to 10.0 -1.6 0.1
Cas4 Paper feed from optional cassette4. -10.0 to 10.0 -1.6 0.1
Duplex Duplex mode. (second) -10.0 to 10.0 0 0.1
Correct image