2NC/2NF/2NG/2NN/3P7/3P8/3P9-5
1-3-80
Setting: [Adjust OriginalDP]
*: This setting is usually unnecessary.
1. Measure the distance from the leading edge to the black belt (inside) of the original at A.
2. Enter the measured value usingchange keys * or numeric keys in [Lead].
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
3. Measure the distance from the left edge to the black belt (inside) of the original at B.
4. Enter the measured value using change keys * or numeric keys in [Main Scan].
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
5. Measure the distance from the black belt of leading edge (inside) to the black belt of trailing
edge (inside) of the original at C.
6. Enter the measured value using change keys * or numeric keys in [Sub Scan].
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
7. Press the start key. The value is set.
Figure 1-3-18
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
A
C
B
Original for adjustment (P/N: 302AC68243)