2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-42
U099 Detect Org Sz
Description
Checks the operation of the original size sensor and sets the sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the original size sensor mal-
functions frequently due to incident light or the like.
Method
1. Press the start key.
* : Select the item to e set.
Display Description
Data1 Displays the width of an Original Area colored original document
B/W Level1 Setting original size detection threshold value
Data2 Displays the width of an Original Area colored original document (when
DP is installed)
Method: [Data1/Data2]
1. Place the original and close the original cover or DP
2. The light source illuminates and the CCD sensor determines the width of the document. The
original size sensor determines the document is vertical or horizontal. (The document is
detected two times when the DP is installed.)
Display Description Setting
range
Initial setting*
OrgAreaDot Detected original width size(dot). 0 to 7280 0/0
OrgAreaMm Detected original width size(mm). 0 to 308.0 0/0
Size SW L Displays the original size sensor ON/OFF. On /Off 0/0
Setting: [B/W Level1]
1. Select an item to be set.
2. Change the setting value using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
Display Description
Setting
range
Initial setting*
Original1 Original1 threshold value. 0 to 255 50
Original2 Original2 threshold value. 0 to 255 50
Original3 Original3 threshold value. 0 to 255 50
Light Source Light Source threshold value. 0 to 255 49