2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-45
U101 1ST TC Output
Description
Sets the control voltage for the primary transfer.
Purpose
To change the setting when any density problems, such as too dark or light, occur.
Method
1. Press the start key.
2. Select the item to be adjusted.
3. Change the value using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
Display Description Setting range
Initial
setting
On Tmg Transfer bias ON timing. -1000 to 1000 0
Off Tmg Transfer bias OFF timing. -1000 to 1000 0
Pre On Tmg Transfer bias Pre ON timing. -1000 to 1000 0
Bias(L) Transfer bias for large sizes. 0 to 2000 80
Bias(M) Transfer bias for medium sizes. 0 to 2000 110
Bias(S) Transfer bias for small sizes. 0 to 2000 140
Bias H(L) Half Transfer bias for large sizes. 0 to 2000 100
Bias H(M) Half Transfer bias for medium sizes. 0 to 2000 150
Bias H(S) Half Transfer bias for small sizes. 0 to 2000 200
4. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt
copying mode (which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for maintenance item No. is displayed.