2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-44
U100 Main HV Output
Description
Performs main charging.
* : Perform the high altitude settings when a leakage is developed on images in a high altitude
installation, such as in Mexico City.
Purpose
To check main charging.
Method
1. Press the start key.
2. Select the item to be set.
Display
Charged Voltage
High Altitude
Setting: [Charged Voltage]
1. Select the item to be set.
2. Change the value using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
Display Description
Setting
range
Initial
setting
Execute Aging is performed. - -
Voltage The amount of adjustments of charged
voltage.
-100 to 100 0
3. Press the start key. The value is set.
Setting: [High Altitude]
1. Select the mode to be set.
Display Description
Mode0 Set mode0 of high altitude mode. (1500 m or less)
Mode1 Set mode1 of high altitude mode. (1500 m to 2500 m)
Mode2 Set mode2 of high altitude mode. (2500 m or more)
* : Initial setting: 0
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for maintenance item No. is displayed.