2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-40
U074 Adj DP input
Description
Adjusts the luminosity of the exposure lamp for scanning originals from the DP.
Purpose
Used if the exposure amount differs significantly between when scanning an original on the platen
and when scanning an original from the DP.
Setting
1. Press the start key.
2. Change the setting using change keys * or numeric keys.
* : Zoom/Paper selection key (Basic model), Right/Left arrow key (Advanced model)
Display Description
Setting
range
Initial
setting
Change in
value per step
Coefficient DP input light luminosity. 0 to 3 0 1
Settings 0: No correction / 1: Slight correction / 2: Medium correction / 3: Strong correction
3. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt
copying mode (which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.