2NC/2NF/2NG/2NN/3P7/3P8/3P9
1-4-46
5
Shading plate Check whether the shading plate
is dirty.
If the shading plate is dirty, perform
maintenance mode U063 to modify the
shading position. If it does not cure, replace the
contact glass assembly.
(see page 1-3-30)
6
CIS The CIS is defective. Replace the CIS and perform U411.
(see page 1-3-75)
7
Main/Engine PWB The main/engine PWB is defec-
tive.
Replace the main/engine PWB.(see page 2-2-
11)
Defective part Check description Corrective Action