2NC/2NF/2NG/2NN/3P7/3P8/3P9
1-5-99
4. Remove the screw and the ground
terminal.
5. Release two hooks B by pushing two
hooks A to upside and remove the PF
main PWB.
Figure 1-5-172
6. Remove the connector.
7. Remove two screws and remove the PF
paper feed motor.
8. Check or replace the PF feed motor
and refit all the removed parts.
Figure 1-5-173
PF unit
Screw
PF main PWB
Hooks B
Hooks A
Grounding terminal
Screws
PF paper feed motor
Connector