Hydraulic System 265
Rotation can be done by turning the mounting cap clockwise or counter-clockwise with
your hands or by using a metallic bar as illustrated in the above picture.
NOTE: Make sure pump does not come apart.
NOTE: The cartridge will rotate with the housing.
IMPORTANT: Do not pull on the mounting cap because inside components may move and damage the pump.
13 d. Put all 4 bolts back in place.
13 e. Check if the shaft rotates freely.
13 f. Tighten up all bolts to the torque of 138-140 ft-lb.
When tightening bolts, be sure to respect the following number sequence to avoid
damaging the seals: