Figure 219. Hot-swap power supply filler removal
Step 3. Slide the new hot-swap power supply into the bay until it snaps into position.
Figure 220. Hot-swap power supply installation
Step 4. Connect the power supply unit to a properly grounded electrical outlet.
For AC power supply units:
1. Connect one end of the power cord to the power connector on the power supply unit.
2. Connect the other end of the power cord to a properly grounded electrical outlet.
For –48V DC power supply units:
1. Use a slotted screwdriver to loosen the 3 captive screws on the power supply terminal
block.
2. Check the polarity label on the power supply unit and each power cord.
Chapter 4. Hardware replacement procedures 295