EasyManua.ls Logo

Lenovo ThinkSystem SR650 V2 - General Problem Determination Procedures

Lenovo ThinkSystem SR650 V2
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General problem determination procedures
Use the information in this section to resolve problems if the event log does not contain specific errors or the
server is inoperative.
If you are not sure about the cause of a problem and the power supplies are working correctly, complete the
following steps to attempt to resolve the problem:
1. Power off the server.
2. Make sure that the server is cabled correctly.
3. Remove or disconnect the following devices, one at a time, until you find the failure. Power on and
configure the server each time you remove or disconnect a device.
Any external devices.
Surge-suppressor device (on the server).
Printer, mouse, and non-Lenovo devices.
Each adapter.
Hard disk drives.
Memory modules until you reach the minimum configuration that is supported for the server.
Note: The minimum configuration required for the server to start is one processor and one 16 GB
DIMM.
4. Power on the server.
If the problem is solved when you remove an adapter from the server, but the problem recurs when you
install the same adapter again, suspect the adapter. If the problem recurs when you replace the adapter with
a different one, try a different PCIe slot.
If the problem appears to be a networking problem and the server passes all system tests, suspect a network
cabling problem that is external to the server.
386
ThinkSystem SR650 V2Maintenance Manual

Table of Contents

Other manuals for Lenovo ThinkSystem SR650 V2

Related product manuals