Resolving suspected power problems
Power problems can be difficult to solve. For example, a short circuit can exist anywhere on any of the power 
distribution buses. Usually, a short circuit will cause the power subsystem to shut down because of an 
overcurrent condition. 
Complete the following steps to diagnose and resolve a suspected power problem.
Step 1.  Check the event log and resolve any errors related to the power. 
Note: Start with the event log of the application that is managing the server. 
Step 2.  Check for short circuits, for example, if a loose screw is causing a short circuit on a circuit board.
Step 3.  Remove the adapters and disconnect the cables and power cords to all internal and external 
devices until the server is at the minimum configuration that is required for the server to start. See 
“Specifications” on page 2 to determine the minimum configuration for your server.
Step 4.  Reconnect all ac power cords and turn on the server. If the server starts successfully, reseat the 
adapters and devices one at a time until the problem is isolated. 
If the server does not start from the minimum configuration, replace the components in the minimum 
configuration one at a time until the problem is isolated.
Chapter 5. Problem determination 387