7.4 Operating functions
7.4.1 Operating mode
Code Name
Possible settings
IMPORTANT
Lenze Choice Info
C001¤ Operating mode -0- -0- Setpoint selection via term. 8
Control via terminals
Parameter setting via 8201BB
-1- Setpoint selection via 8201BB or
LECOM
Control via terminals
Parameter setting via 8201BB
-2- Setpoint selection via term. 8
Control via terminals
Parameter setting via LECOM
-3- Setpoint selection via LECOM
Control via LECOM
Parameter setting via LECOM
Function With the selection of the operating mode you determine the control, the setpoint selection and the
parameter setting of the drive. This setting should always be made first.
Important When you select the setpoint via the keypad or the motor-potentiometer function, the setpoint will
be saved when switching the mains or interrupting the operation.
When changing the operating mode to setpoint selection via keypad or setpoint selection via
LECOM”, the drive might start after enabling the controller.