Installation
8200SHB0199
4-41
4.2.8.3 Connection diagrams
for 822X/824X only
62
78
9
K11 K12
K14
3k
3k3k
3k3k
Vcc
GND 2
K1
GND 1
5,2V
Vref
3k3
>100k
82XX
R
³
1k
20
28
E1
E2
E3 E4
39
PE
T1 T2
PTC
Sx
K21
K22
K24
K2
FIG 4-24 Control connections: Supply with internal control voltage
for 822X/824X only
62 7
8
9
K11 K12 K14
3k
3k3k3k
3k
Vcc
GND 2
GND 1
5,2V
Vref
3k3
>100k
12...30V
82XX
R
³
1k
+
-
20 28 E1 E2 E3 E4 39
PE
K1
T1 T2
PTC
Sx
K21
K22
K24
K2
FIG 4-25 Control connections: External voltage supply (+12 V ... +30 V)
GND1 Reference for internal voltages
GND2 Reference for external voltages
GND1 and GND2 have a potential isolation inside the unit.
The connections for the motor temperature monitoring (T1, T2) are next to the
connection terminals U, V, W.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com