range
During storage of the controller: -25 C¡+55C
During operation of the controller: 0 C¡+40C
+40C¡+50C
without power derating
with power derating
Permissible installation
height
h $ 1000 ma.m.s.l.
1000 m a.m.s.l. h $ 4000 m a.m.s.l.
without power derating
with power derating
Degree of pollution VDE 0110 part 2 pollution degree 2
Noise emission Requirements to EN 50081-2, EN50082-1, IEC 22G-WG4 (Cv)21
Limit value class A to EN 55011 (industry) with mains filter
Limit value class B to EN 55022 (residential area)withmains filter and installation into control
cabinet
Noise immunity
Limit values maintained with mains filter
Requirements toEN 50082-2, IEC 22G-WG4 (Cv) 21
Requirements Standard Severities
ESD EN61000-4-2 3, i.e. 8 kV with air discharge,
6 kV with contact discharge
RF interference (enclosure) EN61000-4-3 3, i.e. 10 V/m; 27¡1000 MHz
Burst EN61000-4-4 3/4, i.e. 2 kV/5 kHz
Surge
(Surge on mains cable)
IEC 1000-4-5 3, i.e. 1.2/50 ³s,
1 kV phase-phase,
2 kV phase-PE
Insulation strength Overvoltage category III to VDE 0110
Packaging to DIN 4180 Types 820X, 821X, 824X
Types 822X,
821X/2X/4XHVAC (V020)
Dust packaging
Transport packaging
Enclosure
Types 82XX, 82XX HVAC (V020) IP20
NEMA 1: Protection against contact
Types 8215 - 8218, 822X, 824X,
8215/16/17/18/2X/4X HVAC (V020)
IP41 on the heat-sink side with thermal separation in
push-through technique
Approvals
Types 82XX, 82XX HVAC (V020) CE: Low-Voltage Directive and
Electromagnetic Compatibility
Types 822X, 824X,
822X/4X HVAC (V020)
UL 508:
UL 508C:
Industrial Control Equipment
Power Conversion Equipment
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com