Technical Data
8200SHB01993-2
3.2 Features
820X 821X 822X 824X
Compact design
/ / / /
Load capacity of up to150 %I
r
for 1 min
/ / / /
Inverter outputs are protected against short circuit
/ / / /
Earth-fault check at mains connection
/ / / /
Chopper frequency 9.2 kHz
/
Chopper frequency selectable: 4 kHz, 8 kHz, 12 kHz, 16 kHz
/ / /
V/f-characteristic control with constant V
min
boost or auto boost
/
Motor-current control or V/f-characteristic control selectable
/ / /
Mains-voltage compensation
/ / / /
Slip compensation
/ / / /
Adjustable current limitation with V/f-override
/ / / /
PWMconverter with IGBT-power stages
/ / / /
DC-bus connection and brake-chopper connection
/ / / /
Isolated analog input and output
/ / / /
Relay outputs (change-over contact) 1 1 2 2
PLC-compatible digital outputs (I/O module 8275) 3 (option) 3 (option) 3 (option) 3 (option)
Isolated digital inputs with programmable functions 4 4 4 4
Up to 3 JOG frequencies per parameter set
/ / / /
DC-injection brake
/ / / /
TRIP set and TRIP reset function
/ / / /
Motor potentiometer
/ / / /
Output frequency up to 240 Hz / 480 Hz
/
Output frequency up to 480 Hz
/ / /
Flying restart circuit
/ / / /
2 parameter sets
/ / / /
Elapsed time meter
/ / / /
Assembly with thermal separation of the power stage as from
8215E
/ /
Temperature-dependent blower activation
/ /
PTC monitoring of the motor by integrated evaluation option option
/ /
Process and speed controller
/
*
/
*
/
*
Setpoint summation
/
*
/
*
/
*
Level inversion for digital inputs
/
*
/
*
/
*
Priority for digital inputs
/
*
/
*
/
*
Manual/remote changeover (H/Re)
/
*
/
*
/
*
Belt monitoring
/
*
/
*
/
*
Selection of an inverse analog setpoint
/
*
/
*
/
*
Limit frequencies
/
*
/
*
/
*
Ramp function generator S-shape
/
*
/
*
/
*
Motor phase failure detection
/
*
/
*