Installation
8200SHB01994-14
4.1.5 Assembly of the variant 82XX-V003 ”cold plate
4.1.5.1 General
Fields of application
- Application of coolers without separately driven fan:
- If e.g. the cooling air is so contaminated that it is not possible to use
separately driven fans. The performance as well as the service life of the
fan would be reduced.
- High enclosure with thermal separation:
- If thermal separation is required because of the heat generation in the
control cabinet and if the enclosure class of the cooling unit must be
higher than IP41.
- Application of controllers directly in the machine with reduced assembly
depth:
- Machine components adopt the cooling function.
- The drive concept provides common cooling units (water cooler, forced-air
cooler, etc.) for all controllers.
- Because of technical reasons, the convection cooling is not suitable for
continuous powers > 22 kW. Here, forced cooling (e.g. water cooling) is
required.